Every well on one mapliveSee a demo →
Industrial Monitoring Platform

Cloud & On-Premise SCADA for Oil & Gas Operations.

Cloud SCADA for oil & gas operators - or the same platform on-premise on your own servers. Real-time wellhead monitoring with alerts typically within a minute, backed by Siemens & Allen-Bradley PLC programming and industrial control panel fabrication from one Texas team.

<1minTypical Alert Delivery
99.9%Uptime Target
BroadProtocol Coverage
Modbus RTUMQTTOPC-UAEtherNet/IPBACnet/IPDNP3FINS/UDPHTTP POSTReal-Time AlertsTime-Series HistorianSMS AlertsSiemens TIA PortalAllen-Bradley Studio 5000Custom Control PanelsMobile AccessAvailability Per Service AgreementBarnett Shalemidstream experienceTexas oil & gas focusISA-95-AlignedCloud-NativeEncrypted MQTT/TLS Modbus RTUMQTTOPC-UAEtherNet/IPBACnet/IPDNP3FINS/UDPHTTP POSTReal-Time AlertsTime-Series HistorianSMS AlertsSiemens TIA PortalAllen-Bradley Studio 5000Custom Control PanelsMobile AccessAvailability Per Service AgreementBarnett Shalemidstream experienceTexas oil & gas focusISA-95-AlignedCloud-NativeEncrypted MQTT/TLS
MONITORING WELLS ACROSS - PERMIAN BASIN · EAGLE FORD · BAKKEN · HAYNESVILLE

This Is What Your Pumpers See

scada.merobix.com
Merobix dashboard shown with simulated sample data - well tiles and KPIs

Interface shown with simulated sample data for illustration - not live customer telemetry.

CloudOn-PremOEE ISO 22400-2 CloudOn-PremWork Order Management CloudOn-PremAI Process Assistant CloudOn-PremSQL Database Connector CloudOn-PremProcess Fingerprinting On-PremHot Standby Redundancy On-PremRecipe Management ISA-88 CloudOn-PremHART Field Device Config

One Platform.
Every Operation.

Quick to Stand Up
Connect your PLCs, sensors, and RTUs to the cloud on a timeline scoped to your sites - no lengthy on-premise rollout. No servers, no VPN, no IT team required. The gateway is commissioned on a project timeline scoped with you - see why operators pick Merobix.
See how it works →
Alerts typically within a minute
SMS and email alerts typically fire within a minute of any threshold breach - HIHI, HI, LO, LOLO. Monitor from your phone with wellhead monitoring software built for oil & gas operators.
See all features →
Modbus, DNP3, OPC-UA, MQTT & More.
Drivers for the major industrial protocols - Modbus RTU, Modbus TCP, OPC-UA, MQTT, DNP3, BACnet, EtherNet/IP and more - serving industrial operations across many industries: oil & gas, water, manufacturing, agriculture.
See all industries →

Cloud or
On-Premise.

Cloud SCADA
  • → No server required
  • → No install on your side
  • → Automatic updates
  • → We handle infrastructure
On-Premise SCADA
Your own server
  • → Full data control
  • → Air-gapped capable
  • → Hardware locked license
  • → Works without internet

Deciding between the two? Start with our guide to cloud SCADA systems for oil & gas operators.

Watch an Alert Fire

WELL 14 - JOHNSON LEASE LIVE
TUBING PSI
982
HIHI LIMIT 1,050
HIHI
FLOW RATE
1,244
MCF/D
GATEWAY UPTIME
99.91
% - LAST 30 DAYS
MEROBIX ALERT · Well 14 - Tubing PSI 1,052 ≥ HIHI 1,050 · SMS sent to J. Rodriguez

Representative data.

One Team.
Wellhead to Cloud.

TIA PORTAL - MAIN_OB1 [OB1] - LADDER DIAGRAM
1// Pump Start/Stop Logic - Well #1
2NETWORK 1: "Pump Enable"
3 --|I0.0|--[AND]----|I0.1|----( Q0.0 )--
4 // Start_PB AND NOT Stop_PB → Pump_Run
5NETWORK 2: "Pressure Alarm"
6 IF "Wellhead_PSI" > 1050 THEN
7 "HIHI_Alarm" := TRUE;
8 "Pump_Run" := FALSE; // Emergency stop
9 END_IF;
10NETWORK 3: "MQTT Push to Merobix"
11 MB_CLIENT(REQ := "Send_Cycle", DATA := tagPacket);
SIEMENS TIA PORTAL
ROCKWELL STUDIO 5000

From TIA Portal ladder logic to Studio 5000 function blocks - we program, commission, and troubleshoot PLCs for any industrial application.

S7
Siemens 1200 / 1500
AB
ControlLogix / CompactLogix
HMI
Full HMI Integration
PANEL BUILD - BILL OF MATERIALS · WELL #1 CONTROL PANEL FAT-Tested
Siemens S7-1200 CPU 1214C
14 DI / 10 DO / 2 AI
PLC
Allen-Bradley PowerFlex 525
5 HP / 480V / EtherNet/IP
VFD
NEMA 4X Fiberglass Enclosure
24" × 20" × 8" · C1D2 Rated
C1D2
Siemens KTP700 Basic HMI
7" Touch · PROFINET
HMI
Merobix IoT Gateway Module
MQTT · Cloud Push · 4G LTE
IoT
Third-Party DCS
Redundant CPU · OPC-UA · HART
DCS

We design, build, wire, and test control panels from scratch - custom-built, with C1D2 rated enclosure options available. Delivered FAT-tested and ready to install.

UL
508A Listed Assembly
C1D2
Hazardous-Location Options
FAT
Factory Acceptance Test

Built For
Critical Infrastructure.

Industrial operations can't afford downtime or data breaches. Merobix is built with security at every layer - from the hardware gateway at your site to the infrastructure that stores your data, whether that's our cloud or your own on-premise servers. Connections to the platform are encrypted in transit with TLS, sessions require authenticated sign-in, and logins, configuration changes, and alert acknowledgments are recorded in the audit log. Dig deeper in our SCADA security and compliance hub.

TLS 1.3 Encrypted
MFA / TOTP Auth
Availability Per Service Agreement
Full Audit Log
Role-Based Access
Data Isolation Per Customer
C1D2-Rated Hardware Options
No VPN Required
drivers across the major protocol families
Modbus RTU Modbus TCP OPC-UA MQTT DNP3 BACnet/IP EtherNet/IP FINS/UDP HTTP POST Modbus ASCII
End-to-End Encryption
All data in transit is encrypted with TLS 1.3. Gateway-to-cloud, browser-to-API - nothing travels in plaintext.
Multi-Factor Auth
TOTP-based MFA available on all accounts. Session tokens expire automatically. Brute-force lockout after failed attempts.
Isolated Data Per Customer
Each customer's sensor data, users, and sites are isolated per tenant. No shared data pools. Database-level isolation is designed to keep one customer's queries from returning another customer's data.
Full Audit Trail
Every login, config change, and alert acknowledgment is logged with timestamp, user, and IP address. Tamper-evident.
Role-Based Access
Superadmin, Admin, Manager, Operator - each role has strict permissions. Operators can't change configs. Admins can't access billing.
Outbound-Only Gateway
The gateway initiates all connections outbound. No open inbound ports, no VPN tunnels, no firewall changes needed at your site.
TLS 1.3 Encrypted
MFA Available on All Accounts
Availability Per Service Agreement
Full Audit Log
Role-Based Access Control
C1D2-Rated Hardware Options

Monitor Your Assets From Anywhere

Available on iOS and Android

iOS & Android apps included with every plan

Common Questions

What is Merobix and how does it work?

+

Merobix is a SCADA platform available two ways - fully managed in the cloud, or on-premise on your own servers. A small hardware gateway installs at your site, connects to your PLCs or sensors via Modbus, OPC-UA, or MQTT, and streams live data to your dashboard. Monitor everything from a browser or mobile app.

Does Merobix work with Modbus RTU and TCP?

+

Yes. Merobix supports both Modbus RTU (RS-485 serial) and Modbus TCP (Ethernet) - the standard for most wellhead controllers, RTUs, and flow computers in oil & gas.

How fast are SMS alerts when something goes wrong?

+

Merobix typically delivers SMS and email alerts within a minute of a threshold breach. Configure HIHI, HI, LO, and LOLO thresholds on any tag with smart suppression to prevent alert floods.

Do I need servers or an IT team to run Merobix?

+

No. With Merobix cloud hosting there is nothing to install, patch, or maintain - the gateway connects outbound over cellular or Ethernet, with no open firewall ports and no VPN. Prefer to own the infrastructure? The same platform runs on-premise on your servers.

How is Merobix priced?

+

Pricing is custom-quoted to your operation; your quote lists the full fee schedule, and Merobix does not charge per-tag or per-user fees on current plans. Request a quote →

Can Merobix run on-premise?

+

Yes. The same platform that powers Merobix cloud is available as an on-premise deployment on your own servers or VMs. Your data resides on your own infrastructure, and air-gapped or isolated network deployments are supported. Ask about on-premise licensing when you request a demo.

Ready To Connect
Your Operation?

Join industrial operators who’ve moved from blind spots to real-time visibility - without a lengthy on-premise rollout. Running wells in West Texas? See SCADA monitoring for the Midland and Permian Basin.

Or call (903) 307-7300 - you’ll get an engineer, not a sales rep.

Prefer another language? Merobix auf Deutsch · Merobix en Español